2-94 Service Manual
7462
925.27 Incorrect fuser or
fuser lamp detected.
Fuser type = 2
The machine detected a 115 V
lamp in a 220 V machine. The
fuser lamp has an excessive
wattage rating.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to “Fuser unit
assembly removal” on
page 4-16.
925.50 Incorrect fuser or
fuser lamp detected.
Fuser type = 1
Fuser page count has
exceeded life.
The machine detected a 115 V
lamp in a 220 V machine. The
fuser lamp has an excessive
wattage rating.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to “Fuser unit
assembly removal” on
page 4-16.
925.51 Incorrect fuser or
fuser lamp detected.
Fuser type = 1
Fuser page count has
exceeded life.
The machine detected a 115 V
lamp in a 220 V machine. The
fuser lamp has an excessive
wattage rating.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to “Fuser unit
assembly removal” on
page 4-16.
925.52 Incorrect fuser or
fuser lamp detected.
Fuser type = 1
Fuser page count has
exceeded life.
The machine detected a 115 V
lamp in a 220 V machine. The
fuser lamp has an excessive
wattage rating.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to “Fuser unit
assembly removal” on
page 4-16.
925.75 Incorrect fuser or
fuser lamp detected.
Fuser type = 2
Fuser page count has
exceeded life.
The machine detected a 115 V
lamp in a 220 V machine. The
fuser lamp has an excessive
wattage rating.
1. Turn the machine off/on
and ensure the fuser unit
assembly is properly
installed.
2. Ensure the proper voltage
fuser is installed in the
machine.
3. Replace the fuser unit
assembly if problem
remains. Go to “Fuser unit
assembly removal” on
page 4-16.
Error
code or
message
Error contents Description/Action Possible repair actions