Chapter 6 Motion Function Blocks
(4) Example program
This example program shows the setting of the current position to 200,000,000 position by adding a relative position
(Relative=1) corresponding to the set value (50,000,000) from the current position of 150,000,000.
(a) Function block setting
(b) Timing diagram