Chapter 6 Motion Function Blocks
6.6.19 Write inverter control word (LS_InverterControl)
LS_InverterControl
AxisAxis
Execute Done
UINTUINT
BOOL BOOL
Error BOOL
ErrorID WORD
SwitchOnBOOL
VoltageEnBOOL
QuickStopBOOL
EnableOPBOOL
EnableRampBOOL
UnlockRampBOOL
ReferenceRampBOOL
FaultResetBOOL
HaltBOOL
Specify the axis to be commanded (1~32: real axis)
Set the inverter control word in the rising Edge.
It indicates whether or not the inverter control word setting is done normally.
Indicate whether an error occurs or not.
Output the number of error occurred while motion function block is running.
(1) This motion function block is the function block that sets the control word of the connected inverter when controlling the
inverter by the axis.
(2) In order to operate the inverter, the control word must be set to enable operation.