Chapter 11 Datalog Function
11.6.1 Event Condition
Event Save function runs under Single Condition, Multiple Condition. The setting item for single/operation conditions are
as follows. Multiple Condition runs by connecting Single Condition using operation. Up to 4 Single Conditions can be set
to form a condition. When the Trigger Condition occurs and data saving initiates, E character string is inserted into the
first data string to indicate the event occurrence.
(1) Single Condition
Single Condition runs under BIT Condition, WORD Condition.
(a) BIT Condition
BIT condition checks the set device BIT value, and collects data by detecting trigger when the value is either
[elevation], [descent], [transfer], [ON], or [OFF].
(b) WORD Condition
Word Condition compares the set device with the input value, and converts them into TRUE or FALSE. If the set
device value satisfies the input condition, saves data when the value is [elevation], [descent], [transfer], [ON], or
[OFF].
Ex) If set value is >50, elevation condition