Chapter 6 Motion Function Blocks
6.8.6 Feed hold (NC_FeedHold)
NC_FeedHold
NcChannelNcChannel
Enable Status
UINTUINT
BOOL BOOL
Valid BOOL
Error BOOL
ErrorID WORD
Set the NC channel to make the command.
The NC channel will be in Feed Hold status while the input is enabled.
Indicate the Feed Hold status.
Indicate the validity of the function block output.
Indicate whether an error occurs or not.
Output the number of error occurred while motion function block is running.
(1) This motion function block is to make the Feed Hold command to the corresponding NC channel under the NC control.
(2) If the NC_FeedHold is executed during the automatic operation, the automatic operation is stopped.
(3) If the NC_CycleStart is performed during the execution of the NC_FeedHold command, the NC_CycleStart command is
ignored.