(3) ConveyorAxis can be set to between 1 and 32. An axis belonging to the axes group set as AxesGroup cannot be designated.
(4) The operation parameter of the axis designated as ConveyorAxis must be in mm/inch.
(5) Infinite running repeat must be set for the operation parameter of the axis designated as ConveyorAxis
(6) Synchronized conveyor operation is terminated by performing coordinate system operation using the PCS coordinate system
or performing PCS setting with MC_SetCartesianTransform function block.
(7) Refer to chapter 8.4.9 synchronized conveyor operation in motion controller’s manual for more details