Chapter 11 Datalog Function
(c) Select [Event Condition] and [Multiple Condition] to activate the condition setting window which allows for up to 4
inputs.
(d) Select the timing of data saving at the Event Occurrence Condition and set the operation condition to OR
operation. The number and timing of data change depending on the set value.
(e) Select each condition setting menu one by one, inputting specific set values. [Multiple Condition] activates Event
Condition by calculating [Single Conditions] using the set run method. The basic setting is performed in the same
way as Single Condition.