EasyManuals Logo

Olympus 38DL PLUS User Manual

Olympus 38DL PLUS
318 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #103 background imageLoading...
Page #103 background image
DMTA-10004-01EN, Rev. D, November 2016
Software Options
91
7. Software Options
You can increase the capability of the already versatile 38DL PLUS using the available
software options (see Table 4 on page 91).
When you purchase a software option with the original 38DL PLUS order, the option
is already activated. You can also purchase software options later. You can activate the
software options without having to return the instrument to the factory, by entering
an activation code in the instrument (see “Activating Software Options” on page 92).
Contact your local Olympus representative for more information regarding ordering
software options. Refer to Table 42 on page 285 for the software option part numbers.
Table 4 38DL PLUS software options
Option Description
HIGH RESOLUTION
(see “High Resolution
Software Option” on page 93)
Increases the thickness resolution to 0.001 mm or
0.0001 in. for single element transducers with a
frequency 2.25 MHz.
OXIDE LAYER
(see “Oxide Layer Software
Option” on page 93)
Allows the 38DL PLUS to measure the thickness
of both the boiler tube and its internal oxide.
MULTIMEASUREMENT
(see “Multi-Measurement
Software Option” on page 99)
Allows the 38DL PLUS to measure and display up
to four different layer thicknesses at the same time
using single element transducers.
HIGH PENETRATION
(see “High Penetration
Software Option” on
page 111)
Allows the 38DL PLUS to use low-frequency
single element transducers (as low as 0.5 MHz) for
thickness measurement in attenuating and sound
scattering materials.

Table of Contents

Other manuals for Olympus 38DL PLUS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Olympus 38DL PLUS and is the answer not in the manual?

Olympus 38DL PLUS Specifications

General IconGeneral
Operating Temperature-10 °C to 50 °C (14 °F to 122 °F)
Data LoggerYes
InterfaceUSB, RS-232
Thickness Range0.08 mm to 635 mm (0.003 in. to 25 in.) depending on material and transducer
DisplayBacklit LCD
Battery TypeThree alkaline or NiMH AA cells
PulserAdjustable square wave pulser
Receiver Bandwidth0.5 MHz to 20 MHz
LanguagesEnglish, French, German, Spanish, Italian, Russian, Japanese, Chinese
Resolution0.001 mm or 0.0001 in.
Transducer Frequency2 MHz to 30 MHz
MaterialPlastic housing