5 - 3
5 Monitor
High-function General-purpose Inverter RX2 Series User’s Manual
5-1 Frequency Monitor
5
5-1-1 Output Frequency Monitor
5-1 Frequency Monitor
Displays the output frequency of an inverter.
Output frequency monitor adjusts frequency command according to the setting of the accelera-
tion/deceleration time after the inverter starts operation.
Parameter
5-1-1 Output Frequency Monitor
Item Parameter Data Description
Output frequency
monitor
[dA-01] 0.00 to 590.00 (Hz) Displays output frequency.
Output frequency
monitor (with sign)
[dA-12] -590.00 to 590.00 (Hz)
Displays output frequency with sign.
A forward revolution is indicated with +
sign, and a reverse revolution with -.
Time (sec)
Output frequency
monitor [dA-01]
Frequency (Hz)
Frequency command
after calculation
[dA-04]
Operation command