5 Monitor
5 - 28
High-function General-purpose Inverter RX2 Series User’s Manual
5-18 Options Monitor
Displays which option unit is equipped and where it is equipped.
Precautions for Correct Use
• Recognition of an optional unit is performed in the condition the power supply of the optional
unit has been established.
• If the optional unit is poorly connected or damaged, it is regarded as in unconnected state.
Parameter
Item Parameter Data Description
Option slot 1 mounted
state
[dA-81] Option ID
Displays the ID of optional Unit mounted in
the option slot 1.
Option slot 2 mounted
state
[dA-82] Option ID
Displays the ID of optional Unit mounted in
the option slot 2.
Option slot 3 mounted
state
[dA-83] Option ID
Displays the ID of optional Unit mounted in
the option slot 3.
Option ID
ID Optional Unit type Description
00 No
33 RX2-PG PG Option Unit