9 - 81
9 Communications Functions
High-function General-purpose Inverter RX2 Series User’s Manual
9-5 Modbus Communication Register Number List
9
9-5-7 Group H Register List
Precautions for Correct UsePrecautions for Correct Use
The “Register No.” in the table header shows the register number used inside the inverter.
The “Modbus register spec. No.” in the table header shows the register number used to actu-
ally specify the register in the Modbus communication process.
This register number is 1 less than the inverter “Register No.” according to the Modbus com-
munication specifications.
9-5-7 Group H Register List
Register
No.
Modbus
register
spec. No.
Function name
Parameter
No.
R/W Monitor or setting data
Resolution
3A99h 3A98h Auto-tuning selection HA-01 R/W
00: Disabled
01: Non-rotation
02: Rotation
03: IVMS
-
3A9Ah 3A99h
RUN command selection at
Auto-tuning
HA-02 R/W
00: RUN key on LCD operator
01: [AA111]/[AA211]
-
3A9Bh 3A9Ah Online auto-tuning selection HA-03 R/W
00: Disabled
01: Enabled
-
3AA2h 3AA1h
Stabilization constant,
1st-motor
HA110 R/W 0 to 1000 1(%)
3AA7h 3AA6h
Speed response for Async. M,
1st-motor
HA115 R/W 0 to 1000 1(%)
3AACh 3AABh
ASR gain switching mode
selection, 1st-motor
HA120 R/W
00: [CAS] terminal
01: setting switch
-
3AADh 3AACh
ASR gain switching time set-
ting, 1st-motor
HA121 R/W 0 to 10000 1(ms)
3AAEh 3AADh
ASR gain mapping intermedi-
ate speed 1, 1st-motor
HA122 R/W 0 to 59000 0.01(Hz)
3AAFh 3AAEh
ASR gain mapping intermedi-
ate speed 2, 1st-motor
HA123 R/W 0 to 59000 0.01(Hz)
3AB0h 3AAFh
ASR gain mapping Maximum
speed, 1st-motor
HA124 R/W 0 to 59000 0.01(Hz)
3AB1h 3AB0h
ASR gain mapping P-gain 1,
1st-motor
HA125 R/W 0 to 10000 0.1(%)
3AB2h 3AB1h
ASR gain mapping I-gain 1,
1st-motor
HA126 R/W 0 to 10000 0.1(%)
3AB3h 3AB2h
ASR gain mapping P-gain 1
at P-control, 1st-motor
HA127 R/W 0 to 10000 0.1(%)
3AB4h 3AB3h
ASR gain mapping P-gain 2,
1st-motor
HA128 R/W 0 to 10000 0.1(%)
3AB5h 3AB4h
ASR gain mapping I-gain 2,
1st-motor
HA129 R/W 0 to 10000 0.1(%)
3AB6h 3AB5h
ASR gain mapping P-gain 2
at P-control, 1st-motor
HA130 R/W 0 to 10000 0.1(%)
3AB7h 3AB6h
ASR gain mapping P-gain 3,
1st-motor
HA131 R/W 0 to 10000 0.1(%)
3AB8h 3AB7h
ASR gain mapping I-gain 3,
1st-motor
HA132 R/W 0 to 10000 0.1(%)
3AB9h 3AB8h
ASR gain mapping P-gain 4,
1st-motor
HA133 R/W 0 to 10000 0.1(%)
3ABAh 3AB9h
ASR gain mapping I-gain 4,
1st-motor
HA134 R/W 0 to 10000 0.1(%)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron RX2 Series and is the answer not in the manual?

Omron RX2 Series Specifications

General IconGeneral
BrandOmron
ModelRX2 Series
CategoryInverter
LanguageEnglish

Related product manuals