3.
Select the parent interface [eth0-eth1], type in your VLAN ID, and click submit.
Repeat the process as necessary.
Your new VLAN interfaces will now be displayed in the VLAN Setup panel, listed as eth[#].
[VLAN ID].
2.14.10 System Time Message
The System Time Message is a feature used for special applications that require a once-
per-second time message to be sent out by SecureSync via multicast. This time message
will be transmitted before every 1PPS signal, and can be used to evaluate accuracy and jit-
ter.
To set up and enable a System Time Message:
1.
Navigate to MANAGEMENT > Network Setup > Actions panel, and select Sys-
tem Time Message. The Settings window will open.
2.
Populate the fields Multicast Address, Port Number and Message ID, and click
Submit.