Notes:
The u-blox M8T receiver now uses Land to indicate it will RESURVEY on reboot,
and Stationary to indicate it will not resurvey after reboot.
3.3.3.5 Performing a GNSS Receiver Survey
Note: This topic only applies to stationary applications in Mobile receiver
mode NO surveys will be carried out since the position is updated con-
tinuously.
When SecureSync's integrated GNSS receiver performs a survey, it tries to determine or
verify its geographic position with high accuracy. An accurate geographic position is
required to calculate a precise system time from the GNSS reference.
During a GNSS survey, the position will be iteratively recalculated while gradually increas-
ing the position accuracy. A survey can take up to 33minutes, but typically SecureSync will
synchronize earlier, i.e. offer a valid Timeand 1PPS reference, once it has obtained a suf-
ficiently accurate preliminary position.
Note: If a system has been moved, in Standard receiver mode and Land
Dynamics , receivers will automatically re-survey on reboot. In Standard
mode and Stationary Dynamics, the unit will survey only once, and will not
re-survey on reboot.
Verifying GNSS Survey Progress
To see if SecureSync's GNSS receiver is performing a survey and if so, verify its progress:
1.
Navigate to INTERFACES > REFERENCES: GNSS 0.
2.
The survey status (ACQUIRING, COMPLETE, or progress in percent) is displayed
under the line item Survey Progress.
214
CHAPTER 3 SecureSync 2400 User Manual Rev. 2
3.3 Managing References

Table of Contents

Other manuals for Orolia SecureSync 2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Orolia SecureSync 2400 and is the answer not in the manual?

Orolia SecureSync 2400 Specifications

General IconGeneral
BrandOrolia
ModelSecureSync 2400
CategoryRecording Equipment
LanguageEnglish