E x a m p l e m e s s a g e :
T:ye:mo:da:dw:ho:mi:sc
Where:
T Indicates the synchronous moment for the time setting.
ye Year (00-99)
mo Month (01-12)
da Day of month (01-31)
dw Day of week (01=Monday to 7=Sunday)
ho Hours (00-23)
mi Minutes (00-59)
sc Seconds (00-59)
5.4.14.2 Format BBC-02
This is a hexadecimal frame/message sent twice per second. The message should be sent
such that the final 99” occurs at 0msec and 500msec.
Number of bytes: 26
Format:
START Year Month Day Hour Min Sec.
AA AA 07 DA 06 16 13 59 01
Millisecond
Time
Zone
Daylight
Leap-
second
Sign
Leap-
second
Month
Leap-
second
Zone
GPS
Week
02 BA 80 00 00 00 00 00 1A 2A
GPS Second GPS to UTC Offset Check-sum END
09 3A 7E 12 FE 99 99
538 SecureSync 2400 User Manual