EasyManua.ls Logo

Orolia SecureSync 2400 - Endrun Formats; Endrun Time Format

Default Icon
589 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Format1: Time Transfer (5101)
Format2: Current Status (5040)
Format3: Buffer Box (253)
A configuration of Current Status as Message Format1 and Time Transfer as Format2 res-
ults in broadcasting of the messages Current Status (1Hz), Time Transfer (1Hz), and Buffer
Box (1/6Hz) at their default rates.
Format1: Current Status (5040)
Format2: Time Transfer (5101)
Format3: Buffer Box (253)
5.4.16 EndRun Formats
The following formats provide compatibility with EndRun technology.
5.4.16.1 EndRun Time Format
E x a m p l e m e s s a g e :
T YYYY DDD HH:MM:SS zZZ m<CR><LF>
Where:
T Time Figure of Merit character (TFOM), limited to the range 6 to 9:
9 indicates error >±10 milliseconds, or unsynchronized condition
8 indicates error <±10 milliseconds
7 indicates error <±1 millisecond
6 indicates error <±100 microseconds
YYYY Year
DDD Day of Year (001-366)
HH Hour of the day (00-23)
: Colon Separator
MM Minutes of the hour
SS Seconds (00-59), (00-60 for leap second)
544 SecureSync 2400 User Manual
APPENDIX

Table of Contents

Other manuals for Orolia SecureSync 2400