Issuing a HALT Command via SerialPort/Telnet/SSH:
With a serial connection to the front panel USB or rear panel serial port, telnet connection
or SSH connection, type halt <Enter> to halt the unit for shutdown. For more information
on SecureSync commands, see "CLICommands" on page514.
Note: After issuing the HALT command wait 30 seconds before you
remove power.
Issuing a HALT Command via the Front Panel:
1.
Press the POWER menu button to switch the front panel display to the Power
Menu. Verify that you are under the Management sub menu (use the left and right
arrow keys if necessary).
2.
Press DOWN until Halt is highlighted. Press the ENTERbutton in the center of the
keyapd once to activate the halt, and then press it again to confirm your choice in
the confirmation menu to the right.
Once you have halted your SecureSync, power must be removed (unplugged) and
reapplied in order to restart the unit.
4.1.4 Rebooting the System
To reboot SecureSync via the Web UI:
1.
Navigate to TOOLS > SYSTEM: Reboot/Halt.
2.
Select the Restart after Shutdown box in the Reboot/Halt window.
3.
SecureSync will now be rebooted and be accessible again shortly thereafter.
Rebooting via LCD/Keypad, Serial Port, Telnet, SSH, SNMP
With a serial connection to the front panel serial port, telnet connection or SSH con-
nection, type reboot <Enter> to reboot SecureSync.
240
CHAPTER 4 • SecureSync 2400 User Manual Rev. 2
4.1 Powering Up/Shutting Down