1.
Navigate to the Contract tab of the GB PTP Edit window.
2.
Under the Contract tab of the GB PTP Edit window, make the following settings:
Min Sync Interval: The minimum value of Sync interval granted by the
Master Clock. In packets per second.
Max Sync Duration: The maximum value of Sync interval granted by the
Master Clock. In seconds.
Min Announce Interval: The minimum value of the Announce interval gran-
ted by the Master Clock. In packets per second.
Max Announce Duration: The maximum value of the Announce interval gran-
ted by the Master Clock. In seconds.
Min Delay_Req Interval: In packets per second.
Max Delay_Req Duration: In seconds.
Max Slaves: The maximum number of slaves to be served. The 1204-32 mod-
ule can serve up to 4000 slaves (unicast contracts).
5.2.7 Miscellaneous Option Cards
This section contains technical information and SecureSync Web UI procedures pertaining
to option cards that do not fall into other categories, e.g. cards that serve as signal relays.
478 SecureSync 2400 User Manual