Reboot is also is available to be performed through an snmpset operation. For more inform-
ation on SecureSync commands, see "CLICommands" on page514.
Once the Reboot process has been initiated, the front panel LCD will display a Power off
message, and the front panel LED time display will stop incrementing until SecureSync has
started booting back up again.
Rebooting via the front panel
1.
Press the POWER menu button to switch the front panel display to the Power
Menu. Verify that you are under the Management sub menu (use the left and right
arrow keys if necessary).
2.
Press DOWN until Reboot is highlighted. Press the ENTERbutton in the center of
the keyapd once to activate the halt, and then press it again to confirm your choice
in the confirmation menu to the right.
During reboot, the front panel display will read Rebooting and the time display will stop
incrementing.
4.2 Notifications
If an event occurs e.g., SecureSync transitions into Holdover, or a short is detected in the
GNSS antenna, SecureSync can automatically notify users that a specific event has
occurred.
In some situations, two events are generated. One event occurs in the transition to a spe-
cified state and then another event occurs when transitioning back to the original state.
Examples of these are losing sync and then regaining sync, or going into Holdover mode
and then going out of Holdover mode. Other situations may only consist of one event. An
example of this situation is switching from one input reference to another.
Notifications of each event that may occur can be via alarms, via SNMP Traps being sent to
one or more SNMP Managers, via an email being sent to a specified email recipient, or a
combination of the three. The Notifications page allows a user to configure whether the
occurrence of each event automatically triggers an alarm to be generated, an SNMP trap
to be sent out, an email to be sent out, or a combination of the three.
Also, this page allows the desired email recipient’s address for that particular event to be
specified. Each event can be configured with the desired email address that is specific to
just that one event only. Note that only one email address can be specified in each Email
Address field. If desired, the same email address can be used in all of the fields, or different
addresses can be used for different events.
4.2 Notifications
CHAPTER 4 SecureSync 2400 User Manual Rev. 2
241

Table of Contents

Other manuals for Orolia SecureSync 2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Orolia SecureSync 2400 and is the answer not in the manual?

Orolia SecureSync 2400 Specifications

General IconGeneral
BrandOrolia
ModelSecureSync 2400
CategoryRecording Equipment
LanguageEnglish