Telnet/SSH: For limited remote configuration
Security features: Up to 32-character password, Telnet Disable, FTP Disable, Secure
SNMP, SNMP Disable, HTTPS/HTTP Disable, SCP, SSH, SFTP.
Authentication: LDAP v2 and v3, RADIUS, MD5 Passwords, TACAS+.
1.6.11 Mechanical and Environmental Specifications
Dimensions:
Designed for EIA 19” rack mount:
Housing w/o connectors and brackets:
16.75” W x 1.72 H [1U] x 14.33 D actual
(425 mm W x 44 mm H x 364 mm D)
Weight:
6.0 lbs (2.72 kg)
Temperature:
Operating:
–2C to +65°C (55°C with Rubidium oscillator option)
Storage:
–40°C to +85°C
Humidity:
10% - 95% relative humidity, non-condensing @ 40°C
Altitude:
Operating:
100-240 V
AC
: up to 13120 ft (3999 m)
Storage range:
up to 45000 ft (13716 m)
Shock and Vibration:
Operating:
ETSI EN 300 019-2-3 Class 3.2; IEC 60721-3-3 Class 3m12
Storage:
ETSI EN 300 019-2-3 Class 3.2; IEC 60721-3-3 Class 3m12
MIL-STD-810:
501.6, 502.6, 503.6, 507.6, 500.6, 516.7, 514.7