FL_SYNC_SYS_REF_NONE ('X') Never been in sync
FL_SYNC_SYS_REF_YES (' ') In sync with a reference
FL_SYNC_SYS_REF_LOST ('F') Out of sync, lost reference
5.4.13 Spectracom Epsilon Formats
5.4.13.1 Spectracom Epsilon TOD1
This message corresponds to the TOD1 format provided by EPSILON 2S/3S Series
products on RS232/422 ports.
The structure of this format is as follows:
<space>DD/MM/YYYY<space>HH:MM:SST(CR)(LF)
Length=23 bytes
Where:
<space> separator
DD 2-digit Day of month
</> separator
MM 2-digit Month
</> separator
YYYY 4-digit Year
<space> separator
HH 2-digit Hour
: separator
MM 2-digit Minutes
: separator
SS 2-digit Seconds
T 1-digit Timescale ( 'N' None, 'G' GPS, 'U' UTC, 'A' TAI, 'L' Local, 'M' Manual)
(CR) Carriage Return (ASCII Character 13 0x0D)
(LF) Line Feed (ASCII Character 10 0x0A)