whether or not to become the active Master Clock. The BMC algorithm selects the
Best Master Clock on the network from the following criteria:
i.
The BMC algorithm first selects the clock having the higher Priority1 para-
meter (a lowest value means a higher priority).
ii.
If the BMC cannot be determined from the previous parameter, the BMC
algorithm selects the clock having the higher Clock Quality (Clock Class, Clock
Accuracy, Clock Variance).
iii.
If the BMC cannot be determined from the previous parameters, the BMC
algorithm selects the clock having the higher Priority2 parameter.
The Master Clock selected by the BMC algorithm as the Best Master Clock will transition
into the Master state to become the active Master Clock on the network. It will then start to
transmit Sync packets to the Slave Clocks. The other Master Clocks will transition into the
Passive state.
Enabling PTP
To enable PTP:
1.
Navigate to the Top panel of the GB PTP Edit window.
2.
Check the Enable PTP box.
Configuring Multicast Mode
To enter Multicast mode, perform the following steps:
1.
In the GB PTP Edit window, navigate to the Advanced tab.
2.
Select the Multicast Sync checkbox.
3.
Select the Multicast Sync Rate from the drop-down list.
SecureSync 2400 User Manual 475
APPENDIX

Table of Contents

Other manuals for Orolia SecureSync 2400

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Orolia SecureSync 2400 and is the answer not in the manual?

Orolia SecureSync 2400 Specifications

General IconGeneral
BrandOrolia
ModelSecureSync 2400
CategoryRecording Equipment
LanguageEnglish