Additional information on the SIMOGEAR geared
motor
12
12.1 General information geared motor with SINAMICS G115D Motor
Mounted / Wall Mounted
12.1.1 Specic hazard types and fundamental obligations
WARNING
Hot, escaping oil
Before starting any work wait until the oil has cooled down to below +30°C.
WARNING
Poisonous vapors when working with solvents
Avoid breathing vapors when working with solvents.
Ensure adequate ventilation.
WARNING
Risk of explosion when working with solvents
Ensure adequate ventilation.
Do not smoke.
Comply with the following safety instructions:
In addition to the specied personal protection gear, also wear suitable protective gloves and
safety glasses.
Comply with the notes on the rating plates attached to the geared motor. The rating plates
must be kept free from paint and dirt at all times. Replace any missing rating plates.
Collect and dispose of used oil in accordance with regulations. Immediately remove any oil
spills with an oil-binding agent.
Do not use high-pressure cleaning equipment or sharp-edged tools to clean the geared motor.
The machine OEM who installs the geared motors in a plant must include the regulations
contained in the operating instructions in its own operating instructions.
During operation, comply with the vibration levels according to ISO20816‑1. Maximum
permissible vibration values can be found in Installation notes (Page435).
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA 427