EasyManua.ls Logo

Siemens SINAMICS G115D

Siemens SINAMICS G115D
600 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7.9.2.3 Turntable, three positions and one speed (p3393 = 7)
Overview
With p3393 (conveyor technology application) set to 7, the converter enables a turntable in a
conveyor system to rotate in either positive or negative direction with a 󹪝xed speed and stop at
three dedicated positions. Three sensors are required to signal the limit positions for the motor
to stop.
Precondition
You interconnect the signals of the sensors with the digital inputs of your choice.
Depending on the speci󹪝c application and mechanical setup, you must set end position
shutdown active (p3392) to 1, so as to limit the turntable movement between the dedicated
positions.
Advanced commissioning
7.9Conveyor technology control functions (for G115D PROFINET and AS-i variants only)
SINAMICS G115D Wall Mounted distributed drive
202 Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA