In the case of storage in transit over 6months, special arrangements must be made for
preservation. Contact the Technical Support.
Store the gearbox or geared motor in dry, dust-free rooms that are maintained at a constant
temperature.
The storage location must be vibration- and shock-free.
The free shaft ends, sealing elements and ange surfaces must have a protective coating.
Do not store the geared motor on the fan cover.
Storage up to 36months (optional)
Store the gearbox or geared motor in dry, dust-free rooms that are maintained at a constant
temperature. Special packing is then not necessary.
If such premises are not available, pack the gearbox or the geared motor in plastic lm or
air-tight sealed lm and materials. The lms and materials must be able to absorb moisture.
Cover them to provide protection against heat, direct sunlight and rain.
The permissible ambient temperature is -25°C to +50°C.
The life of the corrosion protection is 36months from delivery.
12.2.8 Installation conditions for the motor
NOTICE
Risk of overheating due to insucient cooling
Protect intake and discharge openings against blockages and coarse dust.
The cooling air must ow unimpeded into the air intakes and ow out through the air outlets.
Exhaust air should not be drawn back in again.
Motor Mounted Wall Mounted
Figure12-6 Minimum clearance of motor with G115D from wall for air intake
Additional information on the SIMOGEAR geared motor
12.2Specic data motor
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA 451