12.1.3.2 Painted version
The corrosion protection system is classi󹪝ed according to the corrosiveness categories in
DINENISO12944‑2.
Paint according to corrosiveness categories
Paint system Description
Corrosiveness category C1, unpainted for gearbox and motor housings made of aluminum
-
Indoor installation
Heated buildings with neutral atmospheres
Resistance to greases and some resistance to mineral
oils, aliphatic solvents
Standard
Paint system Description
Corrosiveness category C1 for normal environmental stress
1‑component hydro paint, top coat
Indoor installation
Heated buildings with neutral atmospheres
Resistance to greases and some resistance to mineral
oils, aliphatic solvents
Standard paint for gearbox housings made of cast iron
Paint system Description
Corrosiveness category C2 for low environmental stress
2‑component - polyurethanetop coat
Indoor and outdoor installation
Unheated buildings with condensation, production
areas with low humidity, e.g. warehouses and sports
facilities
Atmospheres with low levels of pollution, frequently
rural areas
Resistance to greases, mineral oils and sulfuric
acid(10%), caustic soda(10%) and is conditionally
resistant to aliphatic solvents
Additional information on the SIMOGEAR geared motor
12.1General information geared motor with SINAMICS G115D Motor Mounted / Wall Mounted
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA 429