Paint system Description
Corrosiveness category C3 for medium environmental stress
2‑component epoxy zinc phosphate base
coat,
2‑component polyurethane top coat
Indoor and outdoor installation
Production areas with high humidity and some air
contamination, e.g.food production areas, dairies,
breweries and laundries
Urban and industrial atmospheres, moderate contam‐
ination from sulfur dioxide, coastal areas with low salt
levels
Resistance to greases, mineral oils, aliphatic solvents,
sulfuric acid(10%), caustic soda(10%)
Paint system Description
Corrosiveness category C4 for high environmental stress
2‑component epoxy zinc phosphate base
coat,
2‑component polyurethane top coat
Indoor and outdoor installation
Chemical plants, swimming pools, wastewater treat‐
ment plants, electroplating shops, and boathouses
above seawater
Industrial areas and coastal areas with moderate salt
levels
Resistance to greases, mineral oils, aliphatic solvents,
sulfuric acid(10%), caustic soda(10%)
Paint system Description
Corrosiveness category C5 for very high environmental stress
2‑component epoxy zinc phosphate base
coat,
2‑component polyurethane intermediate
coat,
2‑component polyurethane top coat
Indoor and outdoor installation
Buildings and areas with almost constant condensa‐
tion and high levels are contamination, e.g.malt fac‐
tories and aseptic areas
Industrial areas with high humidity and aggressive at‐
mosphere, coastal areas and o󹪜shore environments
with high salt levels
Resistance to greases, mineral oils, aliphatic solvents,
sulfuric acid(10%), caustic soda(20%)
In case of corrosiveness category C1, overpainting with a 1‑component hydrosystem after
prior rubbing down is possible.
In case of corrosiveness categories C2toC5, overpainting with 2‑component polyurethane
paint, 2‑component epoxide paint and 2‑component acrylic paint after prior rubbing down is
possible.
Additional information on the SIMOGEAR geared motor
12.1General information geared motor with SINAMICS G115D Motor Mounted / Wall Mounted
SINAMICS G115D Wall Mounted distributed drive
430 Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G115D and is the answer not in the manual?

Siemens SINAMICS G115D Specifications

General IconGeneral
TypeSINAMICS G115D
Frequency Range0 Hz to 550 Hz
Safety IntegratedSTO (Safe Torque Off)
Relative Humidity5% to 95% (non-condensing)
Mounting TypeWall-mounted
Input Voltage380 V to 480 V AC
Communication InterfacesPROFIBUS, PROFINET, USS, Modbus RTU
Control MethodVector Control
Shock ResistanceIEC 60068-2-27
Protection ClassIP65