Table 12-38 Tightening bolt tightening torque
Gearbox type Size Thread size Tightening torque
Strength class12.9 Nm
F, B, C 29 M5 10
F, B, K, C 39
F, B, K, C 49 M6 16
F, K, C 69
F, K 79 M8 38
F, K, C 89
12.3.16.3 Removing SIMOLOC
Procedure
1. Remove all bolts completely.
2. Screw the bolts into the threaded holes .
3. Use the torque wrench to turn each of the bolts  equally (not crosswise), repeating this
procedure several times. Observe the tightening torque of the bolt . Repeat the task until
the tapered bushing has been freed.
4. Unscrew the bolts and remove the tapered bushing .
5. Lower the gearbox from the machine shaft .
You have removed the SIMOLOC assembly system.
Additional information on the SIMOGEAR geared motor
12.3Speci󹪝c data gearbox
SINAMICS G115D Wall Mounted distributed drive
Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA 503

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G115D and is the answer not in the manual?

Siemens SINAMICS G115D Specifications

General IconGeneral
TypeSINAMICS G115D
Frequency Range0 Hz to 550 Hz
Safety IntegratedSTO (Safe Torque Off)
Relative Humidity5% to 95% (non-condensing)
Mounting TypeWall-mounted
Input Voltage380 V to 480 V AC
Communication InterfacesPROFIBUS, PROFINET, USS, Modbus RTU
Control MethodVector Control
Shock ResistanceIEC 60068-2-27
Protection ClassIP65

Related product manuals