Note
Oil sump temperatures above+80°C can reduce service life. A temperature increase by10K
halves the service life by the amount as shown in the 󹪝gure titled "Guide values for oil change
intervals".
For a +80 °C oil sump temperature, the following service life can be expected when observing
the properties speci󹪝ed by Siemens:
Table 12-45 Service life of the oils
Type of oil Service life
Mineral oil 10000operating hours or 2years
Biodegradable oil
Physiologically safe oil according to USDA-H1/-H2
Synthetic oil 20000operating hours or 4years










 
*JOI
5JOp$
Mineral oil
Synthetic oil
T Oil bath steady-state temperature in °C
I Oil change interval in operating hours in h
Figure12-35 Guide values for oil change intervals
Grease service life of roller bearing greases
Roller bearings and the clearance in front are 󹪝lled with su󹪟cient grease.
Under approved operating conditions and ambient temperatures, no regreasing is required.
We recommend that the grease in the bearings is also renewed when the oil or shaft sealing
rings are replaced.
Additional information on the SIMOGEAR geared motor
12.3Speci󹪝c data gearbox
SINAMICS G115D Wall Mounted distributed drive
522 Operating Instructions, 07/2023, FW V4.7 SP14, A5E52808211A AA