Setup
3.4 Inputs and outputs
FST030
Function Manual, 04/2017, A5E35693328-AA
123
Related
Path
Setup → Inputs and outputs → Channel 2 - output → Pulse output → Pulse width units
3.4.4.6.9 Pulse width
Description
Pulse duration.
Setting 0.00 s to 4.00 s
Default
0.10 s
Related
Path
Setup → Inputs and outputs → Channel 2 - outputs → Pulse output → Pulse width
3.4.4.6.10 Polarity
Description
Logical polarity of pulse output.
Setting
Active high level; Active low level
Default
Active high level
Related
Path Setup → Inputs and outputs → Channel 2 - output → Pulse output → Polarity
3.4.4.6.11 Fail-safe behaviour
Description
Current output reaction in case of a fault.
Setting
Last valid value; Hold; Current value; Fail-safe value; Maximum pulses/s (only if CH3 oper-
ation mode is configured to Pulse output and CH3 redundancy mode is set to 90° or 180°.
In case of a fault CH3 will output 0 pulses/s)
Default
Last valid value
Related
Path
Setup → Inputs and outputs → Channel 2 - output → Pulse output → Fail-safe behaviour