EasyManua.ls Logo

Siemens SITRANS F - 2.1 The Channel Setup Menu

Siemens SITRANS F
350 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setup
3.2 Process values
FST030
54 Function Manual, 04/2017, A5E35693328-AA
Related
Path
Setup → Process values → Standard volume flow → Air density at standard conditions
3.2.4
Flow velocity
3.2.4.1
Units
Description
Select units for displayed flow velocity. Units are not applied at communication interface.
Units for flow velocity values.
Setting m/s (meters per second); m/h (meters per hour); in/s (inches per second); in/min (inches
per minute); ft/s (feet per second); ft/min (feet per minute); custom units (see Custom units
/ Custom conversion factor)
Default
m/s (meters per second)
Related
Path
Setup → Process values → Flow velocity → Units
3.2.4.2
Custom units
Description
User specific text string to define custom unit values. The custom unit can then be selected
in the flow velocity units.
Setting
-
Default
-
Related
Path
Setup → Process values → Flow velocity → Custom units
3.2.4.3
Custom conversion factor
Description
Conversion factor for custom unit flow velocity values based on SI velocity units m/s.
Setting
-
Default
1.0