3.4 Inputs and outputs
FST030
Function Manual, 04/2017, A5E35693328-AA
97
3.3.3.10.5 Hysteresis
Description
Hysteresis sets the alarm and warning limits. The hysterious is the distance between the
limits for activation and deactivation of an alarm/warning.
Setting
Process value = Mass flow: 0.00 kg to +9999997952 kg
Process value = Volume flow: 0.00 m³ to +9999997952 m³
Process value = Standard volume flow: 0.00 Sm³ to +9999997952 Sm³
Default Process value = Mass flow: 0.00 kg
Process value = Volume flow: 0.00 m³
Process value = Standard volume flow: 0.00 Sm³
Setup → Totalizers → Totalizer 3 → Alarm and warning limits → Hysteresis
Reset all totalizers
Description
Reset command to reset totalizers 1 to 3 to zero.
Setup → Totalizers → Reset all totalizers
The available configuration of the hardware functionality of input and output is described in
the following table.
Table 3- 1 Hardware and software configuration of the input/output channels
HW configuration
(fixed when ordering)
SW configuration
available to the user