Setup
3.4 Inputs and outputs
FST030
166 Function Manual, 04/2017, A5E35693328-AA
Related
Path
Setup → Inputs and outputs → Channel 3 - relay → On delay
3.4.6.22
Off delay
Description
Set the time delay between resetting alarm condition and de-activating the output.
Setting
0.0 s to 100.0 s
Default
0.0 s
Related
Path
Setup → Inputs and outputs → Channel 3 - relay → Off delay
3.4.7
Channel 4 - input/output
3.4.7.1
Operation mode
Description
Shows the configured Operation mode. Use Change operation mode to set the mode.
Read only.
Setting
Off; Current output; Frequency output; Pulse output; Signal output; Discrete input; Analog
input
Default
Off
Related
Path
Setup → Inputs and outputs → Channel 4 - input/output → Operation mode
3.4.7.2
Change operation mode
Description
Sets operation mode.
Setting
Off; Current output; Frequency output; Pulse output; Status output; Digital input; Current
input
Default
Off