Setup
3.4 Inputs and outputs
FST030
Function Manual, 04/2017, A5E35693328-AA
159
3.4.6.2
Status mode
Description
Select the functionality for the status output.
Setting
Alarm class; Alarm item
Default
Alarm class
Related
Path
Setup → Inputs and outputs → Channel 3 - relay → Status mode
3.4.6.3
Sensor alarms (1)
Description
Selection of alarm items that impact the output. Mainly sensor alarms. Applicable if Status
mode = Alarm item.
Setting
05 DSL voltages; 06 DSL Storage; 07 Flow measurement; 08 DSL internal; 09 Oil Density;
10 Oil Viscosity; 11 Oil spec. gravity; 14 Path 1: No signal; 15 Path 2: No signal; 16 Path 3:
No signal; 17 Path 4: No signal; 19 Electronics temp.; 22 Density calculation; 23 Medium
temp. calc.; 24 Pressure calculation; 25 Viscosity calculation; 26 Sensor temp. comp.; 28
Default
None
Related
Path
Setup → Inputs and outputs → Channel 3 - relay → Sensor alarms (1)
3.4.6.4
Sensor alarms (2)
Description
Selection of alarm items that impact the output. Mainly sensor alarms. Applicable if Status
mode = Alarm item.
Setting
32 Auxiliary input; 34 Invalid flow meas.; 35 Failure on CH5 or CH6; 36 Configuration 2; 37
DSL system monitor
Default
None
Related
Path
Setup → Inputs and outputs → Channel 3 - relay → Sensor alarms (2)