Maintenance and diagnostics
4.5 Peak values
FST030
276 Function Manual, 04/2017, A5E35693328-AA
4.5.2
Process value 2
4.5.2.1
Process value
Description
Assign the process value to be monitored.
Setting
Disabled; Volume flow; Mass flow; Standard volume flow; Sound velocity; Flow velocity;
LiquIdent; Density; Medium temperature; Pressure; Kinematic viscosity; Sensor tempera-
ture (RTD); Auxiliary temperature (RTD); Totalizer 1; Totalizer 2; Totalizer 3
Default
Disabled
Related
If this parameter is set to any other setting than Disabled, parameters
Maximum value
,
Maximum value timestamp
,
Minimum value
,
Minimum value timestamp
and
Reset logging
will be available.
Path
Maintenance and diagnostics → Peak values → Process value 2 → Process value
4.5.2.2
Maximum
Description
Displays maximum measured value.
Related
This parameter is only available if
Process value
is
not
set to Disabled.
Path
Maintenance and diagnostics → Peak values → Process value 2 → Maximum value
4.5.2.3
Timestamp at maximum value
Description
Displays the timestamp when maximum value was measured.
Related
This parameter is only available if
Process value
is
not
set to Disabled.
Path
Maintenance and diagnostics → Peak values → Process value 2 → Maximum value
timestamp