Maintenance and diagnostics
4.5 Peak values
FST030
Function Manual, 04/2017, A5E35693328-AA
279
Timestamp at minimum value
Description
Displays the timestamp when minimum value was measured.
This parameter is only available if
is
set to Disabled.
Path Maintenance and diagnostics → Peak values → Process value 3 → Minimum value
timestamp
Reset peak values
Description
This command is used to reset the logging of the recorded maximum and minimum values
monitored. The drag pointers will be set to the current value.
This parameter is only available if
is
set to Disabled.
Maintenance and diagnostics → Peak values → Process value 3 → Reset logging
Process value
Description
Assign the process value to be monitored.
Setting
Disabled; Volume flow; Mass flow; Standard volume flow; Sound velocity; Flow velocity;
LiquIdent; Density; Medium temperature; Pressure; Kinematic viscosity; Sensor tempera-
ture (RTD); Auxiliary temperature (RTD); Totalizer 1; Totalizer 2; Totalizer 3
If this parameter is set to any other setting than Disabled, parameters
,
,
,
, and
will be available.
Maintenance and diagnostics → Peak values → Process value 4 → Assign process value