Setup
3.1 Sensor settings
FST030
Function Manual, 04/2017, A5E35693328-AA
25
3.1.2.7
Liner settings
Liner thickness
Description
Pipe liner thickness
Setting
0.0 m to 0.5 m
Default
0.0 m
Related
Path
Setup → Sensor settings → Pipe settings → Liner settings → Liner thickness
Liner material
Description
Liner material - Read only. Can only be changed via the Sensor Wizard.
Setting
Read only: Custom; Cement; Coal tar; Enamel; Glass; Plastic; Hi_dens_Poly; PTFE; Rub-
ber
Default
Custom
Related
Path
Setup → Sensor settings → Pipe settings → Liner settings → Liner material
Liner sound velocity
Description
Liner material sound velocity (clamp-on).
Setting
200.0 m/s to 4000.0 m/s
Default
2000.0 m/s
Related
Path
Setup → Sensor settings → Pipe settings → Liner settings → Liner sound velocity
3.1.2.8
Inner pipe roughness
Description
Roughness of inner pipe/liner material.