EasyManua.ls Logo

Siemens SITRANS F - Wall Thickness; Pipe Material; Wall Sound Velocity

Siemens SITRANS F
350 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setup
3.1 Sensor settings
FST030
24 Function Manual, 04/2017, A5E35693328-AA
Related
Path
Setup → Sensor settings → Pipe settings → Outer pipe diameter
3.1.2.4
Wall thickness
Description
Pipe wall thickness.
Setting
1.0
-6
m to 0.5 m
Default
0.001 m
Related
Path
Setup → Sensor settings → Pipe settings → Wall thickness
3.1.2.5
Pipe material
Description
Pipe material - Read only. Can only be changed via the Sensor Wizard.
Setting
Read only: Carbon steel; Stainless steel; ABS plastic; Aluminum; Black iron; Brass; Cast
iron; Copper nickel 70/30; Copper nickel 90/10; Copper; Ductile iron; FRP plastic; Glass;
Hastelloy; Inconel; Kynar plastic; Monel; Nickel; Polyethylene; PVC plastic; Teflon; Titani-
um
Default
Can only be changed via the Sensor wizard
Related
Path
Setup → Sensor settings → Pipe settings → Pipe material
3.1.2.6
Wall sound velocity
Description
Pipe wall material sound velocity (clamp-on).
Use the shear velocity for metallic pipes. Use the longitudinal velocity for plastic pipes.
Setting
200.0 m/s to 4000.0 m/s
Default
3000.0 m/s
Related
Path
Setup → Sensor settings → Pipe settings → Wall sound velocity