EasyManua.ls Logo

Siemens SITRANS F - Page 144

Siemens SITRANS F
350 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setup
3.4 Inputs and outputs
FST030
142 Function Manual, 04/2017, A5E35693328-AA
3.4.5.7.9 Pulse width units
Description
Units of pulse duration value used to configure Ch3 pulse width.
Setting
s (seconds); ms (milliseconds); μs (micro seconds)
Default
s (seconds)
Related
Path
Setup → Inputs and outputs → Channel 3 - input/output → Pulse output → Pulse width units
3.4.5.7.10 Pulse width
Description
Pulse duration.
Setting
0.00 s to 4.00 s
Default
0.10 s
Related
Path Setup → Inputs and outputs → Channel 3 - input/output → Pulse output → Pulse width
3.4.5.7.11 Polarity
Description
Logical polarity of pulse output.
Setting
Active high level; Active low level
Default
Active high level
Related
Path
Setup → Inputs and outputs → Channel 3 - input/output → Pulse output → Polarity
3.4.5.7.12 Fail-safe behaviour
Description
Pulse output reaction in case of a fault.
Setting
Last valid value; Hold; Current value; Fail-safe value
Default
Last valid value