Setup
3.2 Process values
FST030
Function Manual, 04/2017, A5E35693328-AA
73
3.2.11.3.3 Lower warning limit
Description
Falling below this limit causes a warning.
Setting
0.00 kg/m³ to +10000.00 kg/m³
Default
1.00 kg/m³
Related
Path
Setup → Process values → Standard density → Alarm and warning limits → Lower warning
limit
3.2.11.3.4 Lower alarm limit
Description
Falling below this limit causes an alarm.
Setting
0.00 kg/m³ to +10000.00 kg/m³
Default
1.00 kg/m³
Related
Path
Setup → Process values → Standard density → Alarm and warning limits → Lower alarm
limit
3.2.11.3.5 Hysteresis
Description
Hysteresis that affects the alarm and warning limits.
Setting
0.00 kg/m³ to +10000.00 kg/m³
Default
0.00 kg/m³
Related
Path
Setup → Process values → Standard density → Alarm and warning limits → Hysteresis