ID 442426.04 430WE KEEP THINGS MOVING
Diagnosis
16
Manual SD6
16.53 *ParaModul ERROR: ksb write error
16.54 *ConfigStartERROR parameters lost
Triggering Level Response
An error was detected when writing the
configuration in the configuration memory.
— The configuration does not start.
The power stage remains switched off, the drive is free of torque/force. If
there is a brake present it will be released automatically. The brake
chopper is turned off.
Possible cause Test Measure Can be
acknowledge
d
Faulty flash memory. — Replace the Paramodule. No
The configuration is too large for the
configuration memory.
• Apply a suitable configuration via
DriveControlSuite and then save it
(A00).
• Replace the Paramodule.
Triggering Level Response
No parameter values are saved in the
Paramodule.
— The configuration does not start.
The power stage remains switched off, the drive is free of torque/force. A
possibly existing brake will be controlled to close The brake chopper is
turned off.
Possible cause Test Measure Confirmable
The control part was switched off
while A00 was active.
— • Apply a suitable configuration via
DriveControlSuite and then save it
(A00).
• Replace the Paramodule.
No