ID 442426.04 430WE KEEP THINGS MOVING
Diagnosis
16
Manual SD6
16.53 *ParaModul ERROR: ksb write error
16.54 *ConfigStartERROR parameters lost
Triggering Level Response
An error was detected when writing the
configuration in the configuration memory.
The configuration does not start.
The power stage remains switched off, the drive is free of torque/force. If
there is a brake present it will be released automatically. The brake
chopper is turned off.
Possible cause Test Measure Can be
acknowledge
d
Faulty flash memory. Replace the Paramodule. No
The configuration is too large for the
configuration memory.
Apply a suitable configuration via
DriveControlSuite and then save it
(A00).
Replace the Paramodule.
Triggering Level Response
No parameter values are saved in the
Paramodule.
The configuration does not start.
The power stage remains switched off, the drive is free of torque/force. A
possibly existing brake will be controlled to close The brake chopper is
turned off.
Possible cause Test Measure Confirmable
The control part was switched off
while A00 was active.
Apply a suitable configuration via
DriveControlSuite and then save it
(A00).
Replace the Paramodule.
No