VN/UN764:G LgvUvtgco" N4" Ocpcigf" Uykvej" ENK" Iwkfg
288
Rctcogvgt"
multiplier —— Configure the Hold Multiplier parameter. It ranges from 2 to 10.
By default, it is 4.
Eqoocpf"Oqfg"
Global Configuration Mode
Gzcorng"
Specify Hold Multiplier as 5:
VN/UN764:G*eqphki+%nnfr"jqnf/ownvkrnkgt"5"
nnfr"vkogt"
Fguetkrvkqp"
The nnfr" vkogt command is used to configure the parameters about
transmission. To return to the default configuration, please use pq" nnfr" vkogt
command.
U{pvcz"
nnfr"vkogt"{"vz/kpvgtxcn"tx-interval | vz/fgnc{"tx-delay | tgkpkv/fgnc{"reinit-delay |
pqvkh{/kpvgtxcn"notify-interval | hcuv/eqwpv"fast-count }
pq"nnfr"vkogt"{ tx-interval | tx-delay | reinit-delay | notify-interval | fast-count }
Rctcogvgt"
tx-interval —— Configure the interval for the local device to transmit LLDPDU
to its neighbors. The value ranges from 5 to 32768 and the default value is 30
seconds.
tx-delay —— Configure a value from 1 to 8192 in seconds to specify the time
for the local device to transmit LLDPDU to its neighbors after changes occur so
as to prevent LLDPDU being sent frequently. By default, it is 2 seconds.
reinit-delay —— This parameter indicates the amount of delay from when
LLDP status becomes "disable" until re-initialization will be attempted. The value
ranges from 1 to 10 and the default value is 3.
notify-interval —— Specify the interval of Trap message which will be sent from
local device to network management system. The value ranges from 5 to 3600
and the default value is 5 seconds.
fast-count —— When the port's LLDP state transforms from Disable (or
Rx_Only) to Tx&Rx (or Tx_Only), the fast start mechanism will be enabled, that

Table of Contents