EasyManua.ls Logo

Xerox WorkCentre 6605

Xerox WorkCentre 6605
662 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General Information
Xerox Internal Use Only Phaser 6600 and WorkCentre 6605
Service Manual
1-83
Throughput
The sending time is calculated in the following formula:
Sending time = Call setup time + Tm + (N x Tp) + {(N-1) x Tn} + Tu (sec)
(N: Send quantity; Tp: Image transmission time)
Cable Characteristics
With pseudo cable from 0 to 15km, the highest speed shall be guaranteed for communication with
V.17, V.29, and V.27ter. For V.34, 33600bps communication speed shall be guaranteed from 0 to 2km,
31200bps or higher communication speed from 2 to 9km, and 19200bps or higher communication
speed from 9 to 15km.
Communication Load Characteristics
Data error characteristics for noise and cable loss during communication are as follows:
Error rate (Error frequency/Total communication quantity) 1/500
Incoming Call Level
Under ideal conditions (flat line, no noise, and no other line stress), normal communication shall be
guaranteed in the range from -3 through -43dBm.
For V.17, V.29, and V.27ter, the highest speed shall be guaranteed in the range from -6 through -
43dBm. For V.34, 33600bps communication speed shall be guaranteed in the range from -9 through -
19dBm, and 16800bps or higher communication speed in the range from -19 through -43dBm.
For V.34, normal communication shall be guaranteed in the range from -9 through -43dBm.