Service Parts Disassembly
Xerox Internal Use Only Phaser 6600 and WorkCentre 6605
Service Manual
4-143
DADF Assembly / IIT Assembly
PL51.1.2 / PL51.1.3
WARNING: The Fuser is very hot. Take added care when handling the fuser to avoid being burned.
1. Remove the Fuser Assembly. (page 4-46)
2. Remove the Waste Cartridge. (page 4-50)
3. Remove the Waste Cartridge Lock. (page 4-39)
4. Remove the Front Door Assembly. (page 4-128)
5. Remove the Right Cover Assembly. (page 4-131)
6. Remove the Left Cover Assembly. (page 4-136)
7. Remove the Lower Left Hand Rear Cover. (page 4-124)
8. Remove the Upper Right Hand Pole Cover. (page 4-122)
9. Remove the Control Panel Assembly. (page 4-8)
10. Remove the Scanner Assembly. (page 4-138)
11. Turn the Scanner Assembly over.
12. Remove the screw (silver, tapping, 8mm) that attaches the Harness Cover to the IIT Assembly and
remove the cover. Save the cover for re-use during reassembly.
13. Release the IIT Assembly harness from the groove on the underside of the IIT Assembly.
s6600-097