R Commands
rmon hcalarm
359
Cisco Nexus 7000 Series NX-OS System Management Command Reference
OL-25806-03
Usage Guidelines Event number 0 is a predefined null (or no operation) event. When no event is specified by the user in an
alarm, this event is automatically used by the system. The event causes no action to be taken when triggered;
however, the alarm is still reset. The event cannot be redefined by the user. It is a predefined event.
This command does not require a license.
Examples This example shows how to configure a RMON high-capacity alarm:
switch# config terminal
switch(config)# rmon hcalarm 2 1.3.6.1.2.1.31.1.1.1.6.22544384 30 delta
rising-threshold-high 55 rising-threshold-low 3776798720 4 falling-threshold-high 41
falling-threshold-low 3906340864 owner cisco
Related Commands Command Description
rmon alarm Configures a 32-bit RMON alarm.
rmon hcalarm Configures a 64-bit RMON alarm.
show rmon Displays RMON configuration and logging information.