EasyManua.ls Logo

Cisco Nexus 7000 Series

Cisco Nexus 7000 Series
746 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E Commands
event module-failure
156
Cisco Nexus 7000 Series NX-OS System Management Command Reference
OL-25806-03
event module-failure
To specify an event criteria for an Embedded Event Manager (EEM) applet that is run on the basis of a
module failure event, use the event module-failure command. To remove the module failure event
criteria, use the no form of this command.
event module-failure type err-name module {all | module} count count [time interval]
no event module-failure type err-name module {all | module} count count
Syntax Description type err-name Specifies the type of failure condition. Select one of the err-name conditions:
any—Any failure
addon-sequence-failure—Addon sequence failure
hitless-upgrade-diag-failure—Runtime diagnostic failure after hitless upgrade
hitless-upgrade-failure—Hitless upgrade failure
hitless-upgrade-procmgr-notif—LC software failure after hitless upgrade
hitless-upgrade-reg-failure—Registration failure after hitless upgrade
hitless-upgrade-seq-timeout—Hitless upgrade sequence timeout
image-download-failed—Image download failure
image-upgrade-failed—Image upgrade failed
insertion-seq-failure—Insertion sequence failure
lc-failed—LC failed
lc-not-responding—LC not responding
lc-ready-timeout—LC ready timeout
lc-sw-failure—LC software failure
registration-failure—Registration failure
registration-timeout—Registration timeout
runtime-diag-failure—Runtime diag failure
runtime-diag-timeout—Runtime diag timeout
sequence-timeout—Sequence timeout
srg-info-resp-timeout—SRG info response timeout
unexpected-registration—Unexpected registration received
upgrade-srg-not-compatible—Upgrade SRG not compatible
module Specifies that one module or all modules must be monitored.
module Number of a specific module to be monitored.
all Specifies that all modules are to be monitored.
count count Specifies the number of matching occurrences before a module failure event is
triggered. The range is from 0 to 4294967295.
time interval (Optional) Specifies the time interval (in seconds) within which the events need
to happen. The range is from 0 to 4294967295.