S Commands
source exception
402
Cisco Nexus 7000 Series NX-OS System Management Command Reference
OL-25806-03
source exception
To configure the source as an exception Ethernet Switched Port Analyzer (SPAN) or Encapsulated
Remote Switched Port Analyzer (ERSPAN) session, use the source exception command. To remove the
source as an exception SPAN or ERSPAN session, use the no form of this command.
source exception {layer3 | fabricpath | other | all}
no source exception {layer3 | fabricpath | other | all}
Syntax Description
Defaults None
Command Modes config-monitor mode (for a SPAN session)
config-erspan-src mode (for an ERSPAN session)
Supported User Roles network-admin
vdc-admin
Command History
Usage Guidelines M1 and M2 Series modules support exception SPAN only in the nonadministration virtual device context
(VDC), and at least one interface of the module must be present for the VDC.
This command does not require a license.
Examples This example shows how to configure the source as an exception SPAN session:
switch(config)# monitor session 1
switch(config-monitor)# source exception all
This example shows how to configure the source as an exception ERSPAN session:
switch(config)# monitor session 3 type erspan-source
switch(config-erspan-src)# source exception all
layer3 Specifies the Layer 3 exception type for F2 Series and M Series modules.
fabricpath Specifies the FabricPath exception type for F Series modules.
other Specifies exceptions for M Series modules that are dropped through redirect
registers programmed with a drop destination interface.
all Includes all Layer 3, FabricPath, and other exceptions.