Show Commands
show environment
465
Cisco Nexus 7000 Series NX-OS System Management Command Reference
OL-25806-03
Fan:
------------------------------------------------------
Fan Model Hw Status
------------------------------------------------------
Fan1(sys_fan1) 0.0 Ok
Fan2(sys_fan2) 0.0 Ok
Fan3(fab_fan1) 0.0 Ok
Fan4(fab_fan2) 0.0 Ok
Fan_in_PS1 -- -- Ok
Fan_in_PS2 -- -- Ok
Fan_in_PS3 -- -- Absent
Fan Air Filter : Absent
Temperature:
--------------------------------------------------------------------
Module Sensor MajorThresh MinorThres CurTemp Status
(Celsius) (Celsius) (Celsius)
--------------------------------------------------------------------
2 Crossbar(s5) 105 95 40 Ok
2 CTSdev1 (s6) 115 105 47 Ok
2 CTSdev2 (s7) 115 105 51 Ok
2 CTSdev3 (s8) 115 105 47 Ok
2 CTSdev4 (s9) 115 105 48 Ok
2 CTSdev5 (s10) 115 105 47 Ok
2 CTSdev7 (s12) 115 105 50 Ok
2 CTSdev8 (s13) 115 105 50 Ok
2 CTSdev9 (s14) 115 105 48 Ok
2 CTSdev10(s15) 115 105 48 Ok
2 CTSdev11(s16) 115 105 46 Ok
2 CTSdev12(s17) 115 105 45 Ok
2 QEng1Sn1(s18) 115 105 43 Ok
2 QEng1Sn2(s19) 115 105 42 Ok
2 QEng1Sn3(s20) 115 105 39 Ok
2 QEng1Sn4(s21) 115 105 40 Ok
2 L2Lookup(s22) 115 105 43 Ok
2 L3Lookup(s23) 120 110 54 Ok
Power Supply:
Voltage: 50 Volts
-----------------------------------------------------
PS Model Power Power Status
(Watts) (Amp)
-----------------------------------------------------
1 N7K-AC-6.0KW 0.00 0.00 Ok
2 N7K-AC-6.0KW 6000.00 120.00 Ok
3 ------------ 0.00 0.00 Absent
Mod Model Power Power Power Power Status
Requested Requested Allocated Allocated
(Watts) (Amp) (Watts) (Amp)
--- ------------------- ------- ---------- --------- ---------- ----------
2 N7K-M148GT-11 247.00 4.94 247.00 4.94 Powered-Up
6 N7K-SUP1 210.00 4.20 210.00 4.20 Powered-Up
Xb1 N7K-C7010-FAB-1 123.50 2.47 123.50 2.47 Powered-Up