show processes log
595
Cisco Nexus 7000 Series NX-OS System Management Command Reference
OL-25806-03
This example shows how to display detailed information from the process log:
switch# show processes log details
======================================================
Service: aclmgr
Description: ACL Mgr
Started at Thu Mar 13 20:34:35 2008 (507163 us)
Stopped at Thu Mar 13 20:37:07 2008 (664205 us)
Uptime: 2 minutes 32 seconds
Start type: SRV_OPTION_RESTART_STATELESS (23)
Death reason: SYSMGR_DEATH_REASON_FAILURE_SIGNAL (2)
System image name: n7000-s1-dk9.4.0.1.gbin
System image version: 4.0(1) S7
PID: 3632
Exit code: signal 11 (core dumped)
CWD: /var/sysmgr/work
Virtual Memory:
CODE 08048000 - 0811CCF4
DATA 0811DCF4 - 0811EBE8
BRK 08121000 - 08259000
STACK BFFFE270
TOTAL 47244 KB
Register Set:
EBX B7D64CD0 ECX 00000001 EDX 00000001
ESI 41170040 EDI 00000000 EBP BFFFD1C8
EAX 00000401 XDS C010007B XES 0000007B
EAX FFFFFFFF (orig) EIP B7D5BEF2 XCS 00000073
EFL 00010292 ESP BFFFD1C0 XSS 0000007B
Stack: 4272 bytes. ESP BFFFD1C0, TOP BFFFE270
0xBFFFD1C0: B7D5BEE0 B7D64CD0 BFFFD1D8 B7D5C381 .....L..........
0xBFFFD1D0: B7D2614C FF000226 BFFFD218 B7D232BA La..&........2..
0xBFFFD1E0: B5542014 B7D25DE0 000007DE B5542014 . T..]....... T.
0xBFFFD1F0: B7D08918 B7D2614C FF000226 08241A54 ....La..&...T.$.
0xBFFFD200: B5542014 41170034 08241A54 B7D2614C . T.4..AT.$.La..
0xBFFFD210: FF000226 BFFFD2D0 BFFFD278 B7D138CE &.......x....8..
0xBFFFD220: 08246A04 08230074 BFFFD2D0 B7D5A24D .j$.t.#.....M...
0xBFFFD230: B7D6369A 00002000 00000004 00000000 .6... ..........
0xBFFFD240: 0000C005 00002000 BFFFD278 B7D3CF90 ..... ..x.......
...