Show Commands
show rmon
618
Cisco Nexus 7000 Series NX-OS System Management Command Reference
OL-25806-03
switch# show rmon hcalarms
High Capacity Alarm 1 is active, owned by cseSysCPUUtilization.0@test
Monitors 1.3.6.1.4.1.9.9.305.1.1.1.0 every 10 second(s)
Taking absolute samples, last value was 0
Rising threshold is 60, assigned to event 4
Falling threshold is 59, assigned to event 4
On startup enable rising alarm
This example shows how to display RMON configuration and logged information:
switch# show rmon status
Maximum allowed 32 bit or 64 bit alarms : 512
Number of 32 bit alarms configured : 0
Number of 64 bit hcalarms configured : 0
switch#
Related Commands Command Description
rmon alarm Configures the 32-bit RMON alarm.
rmon event Configures an RMON event.