DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
136
Parameters
trap - Specify the trap state.
log - Specify the log state.
none - Neither attack_detected nor attack_cleared is trapped or logged.
attack_detected - Events will be logged or trapped when the BPDU attacks is detected.
attack_cleared - Events will be logged or trapped when the BPDU attacks is cleared.
both - The events of attack_detected and attack_cleared shall be trapped or logged.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To config the bpdu_protection trap state as both for the entire switch:
DGS-3000-26TC:admin#config bpdu_protection trap both
Commands: config bpdu_protection trap both
Success.
DGS-3000-26TC:admin#
enable bpdu_protection 11-4
Description
This command is used to enable BPDU protection function globally for the Switch.
Format
enable bpdu_protection
Parameters
None.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To enable bpdu_protection function globally for the entire switch:
DGS-3000-26TC:admin#enable bpdu_protection
Commands: enable bpdu_protection
Success.
DGS-3000-26TC:admin#